SiDev Software User Manual

1. Software Introduction

This Software can support AI functions such as visible and infrared camera target recognition, target automatic tracking, target manual tracking, moving target counting, moving target tracking, etc., and also support device management, PTZ control, video storage, image capture, false color switching, etc.

chart 1-1 Installation package and program icon

2. Software Function Description

2.1 Software interface

Double click the installation Software icon ,then you can see the starting background images.

Figure 2- 1 Startup interface

The Software interface after startup is as follows:

Figure 2- 2 Program interface

The software supports custom the loading picture. The picture directory is under the res file in the installation directory. Among them, bk.png is the main interface picture, bk1.png and bk2.png are used in the starting background, and bk3.png is the login interface picture.

2.2 Device Login

Click , enter the device, enter the user name: admin, password: admin, then click "Login". This software supports dual waveband camera using both single or dual IP address.

The user name admin is the administrator account, which can fully control the device. User name: user1, password: 12345 is an video reader user account.

Figure 2- 3 Device Login

The current device IP is generally clearly identified on the device shell. If the identification is ambiguous or the IP address has been changed, Onvif Management software can be used to search for devices or MultiDev software can be used to search for devices.

The current video can be observed after logging in to the device.

2.3 Function description

Figure 2- 4 Function description

As shown in the above figure, the upper left of the interface is the algorithm and configuration area, which contains algorithm functions, and the lower right area is the PTZ control and video operation area.

Algorithm and configuration area: including object detection, manual tracking, moving object detection, point to tracking, auto tracking, gate tracking and settings functions.

PTZ control and video operation area: including image and video recording, lens zoom in/out, move to center and move to down, Iris control, PTZ up, down, left and right control, display mode, button hiding functions.

In addition, there are user login and logout button in the upper right corner.

2.4 Algorithm and configuration

2.4.1 Object Detection

Object detection button , click it to turn blue, and this function will be activated. Tofu series products support the recognition of people, vehicles, ships, drones and other targets respectively. Different models support different target types. Conventional models only support the recognition of people and vehicles.

When the target recognition button is activated, the button will be turned blue.

Figure 2- 5 Identification type selection menu

Blue is active, gray is inactive.

2.4.2 Manual Tracking

Click the button , and the function will be activated after it turns blue. After activation, you can draw any square area in the screen, as shown in the following figure. After the area is drawn, the tracking will start automatically.

Figure 2- 6 Manual tracking start

2.4.3 Moving Object detection

Click button to draw a square detection area in the screen after activation. It can automatically lock and track when moving objects are detected.

Figure 2- 7 Moving target detection area drawing

2.4.4 Point to tracking

Click button to activate. This function is to select an interested target from multiple identified targets for tracking. After this button is activated, the target recognition function will be activated automatically and synchronously. The target recognition type is the same as the parameters configured in the target recognition function. After target recognition, click the identified target to start automatic tracking.

2.4.5 Automatic tracking

Click the button to activate. Using this function, target recognition and tracking will running automatically. When multiple targets are identified, the object nearest to the view center will be selected to tracking. If the tracking object is lost, new object which is detected will be selected to track.

2.4.6 Gate tracking

Click button to activate. The gate tracking is a function of tracking with a fixed size of the initial tracking box. There are 32×32,64×64 and 128×128 initial sizes are available. The gate size is not always constant, and will be automatically adjusted according to the scale transformation of the target. In this mode, click any region in the screen to start the gate tracking function.

Figure 2- 8 Gate size selection

2.4.7 Settings

Click the button to pop up the system configuration setting interface.

Figure 2- 9 System configuration interface

The interface includes PTZ control, tracking settings, object tracking, alarmlinkage, image configuration, photoelectric pod, fusion, multiplication table update, version and language.

PTZ control: The Pelco-D protocol ID number of PTZ and camera is configured here. The default PTZ ID is 1.

Tracking Settings: this part of parameters is closely related to identification and tracking, pan tilt control and lens control. See Table 2-1 for the detailed corresponding parameter meanings and default configurations.

Object tracking: parameters in this part include continuous frame difference, zoom effective area, target minimum zoom magnification, target maximum zoom magnification, target recapture interval, automatic zoom (manual zoom or automatic zoom), lost follow up (PTZ stop or follow up option after target loss).

Alarm linkage: including regional intrusion alarm and equipment linkage switch configuration.

Image configuration: configure the image output resolution, encoding method and code rate.

Photoelectric pod: including working mode, display mode, pseudo color mode, digital zoom, local video, AI-OSD, pitch angle setting, heading angle setting, automatic focusing, and algorithm model. See Table 2-3 for detailed corresponding parameters.

Fusion: applicable to image fusion of multispectral camera.

Multiplication table update: select visible light, infrared and laser lens table types, and select the corresponding update file to update the magnification table.

Version and language: This part displays the system version, i.e. the Software software version number, and the device version, i.e. the software version in the board, Chinese and English switch, device restart, factory recovery, and firmware upgrade.

1) PTZ control

Figure 2- 10 PTZ control

Configure the ID numbers of the PTZ and camera. The default is "1".

2) Tracking Settings

Figure 2- 11 Motion control

The configuration value directly determines the velocity change and accuracy of the PTZ in the tracking process. The specific meaning is shown in the table below.

Table 2- 1 Motion control parameters

Parameter name

Default Parameters

explain

Start frames

20

The PTZ operates at a relatively low acceleration within the set frame number,

25 frames/second video frame rate as reference, 20 corresponds to 800ms time

Max speed

20

The maximum speed level of control

Speed gradient

30

During the tracking process, the higher the acceleration of the pan tilt, the greater the acceleration

Difference

5

Control differential adjustment coefficient, 5 by default

Integral

0

Control integral adjustment coefficient, default 0

Manual speed

3

Manual control speed level

3) Object tracking

Figure 2- 12 target tracking

Table 2- 2 Target tracking parameters

Parameter name

Default Parameters

explain

Buffer frame

80

Set value If there is no target recognition within the frame number, it is forced to judge that the target is lost

Auto-zoom Area

50

The picture center is the reference, and the auto zoom operation is performed within the setting value * 10 pixels. The auto zoom function plays a role when it is turned on.

Min Obj focusing

10

If the target size is less than the set value percentage of full frame, zoom lens will zoom in

Max Obj focusing

20

If the target size is greater than the set value percentage of full frame, the zoom lens will be reduced

Retracking delay

0

Time interval for re identification and tracking after target loss, in seconds

Auto-zoom

off

Whether the auto zoom function is enabled

Lost follow-up

off

Whether the PTZ continues to rotate in the original direction after the target is lost.

4) Alarmlinkage

Figure 2- 13 Alarm and linkage

Alarm prompt and linkage switch.

5) Image Configuration

Figure 2- 14 Image Configuration

The resolution, encoding method, and code rate of configurable graphics will be updated and restarted according to the above configuration after clicking “Update”. Updating will take 10 seconds for refreshing.

Table 2- 3 Image Configuration

Parameter name

Default Parameters

explain

Resolution

1080P

Resolution of device video, support to be changed to 1080P, 720P, PAL_D1

Codec

H264

Video encoding type, including H264 and H265

Bit rate

4M

Video bit rate, including 4M, 2M, 1.5M, 1M, 0.5M

Update

After clicking, the device will be updated and restarted according to the above three configurations. After about ten seconds, the device will automatically reconnect.

6) OSD

Figure 2- 155 Software OSD

Controls whether to display lens magnification, pan tilt angle on the top left of the view.

7) Photoelectric pod

Figure 2- 16 Photoelectric pod

Table 2- 4 Photoelectric pod configuration

Parameter name

Default Parameters

explain

Working mode

Follow mode

It is divided into follow mode and lock mode. The default is follow mode, which is only used in UAV pod mode configuration

Display mode

White infrared

The screen display mode includes five display modes: white light infrared, infrared white, single white light, single infrared, and fusion

Color mode

White hot

It supports four pseudo color modes: white hot, black hot, blue hot and red hot, which are only used for thermal infrared devices

Digital zoom

1

Support 1,2,4,6,8x digital zoom configuration, only for thermal infrared devices

Local recording

ON

OFF means recording in the pod, and ON means recording on the PC

OSD

OFF

OSD display switch of photoelectric equipment

laser spot

100

The percentage of laser spot in the vertical range of the picture, which can be adjusted by the adaptive zoom lens, is only used for laser fill type equipment

Pitch angle setting

0

Manually input the specified pitch angle of the pod, which is only applicable to the Litso pod

Heading angle setting

0

Manually input the specified angle of the pod heading, which is only applicable to the Litso pod

Auto focus

open

Automatic focusing switch, manual focusing operation can be carried out when it is off

Algorithmic model

VIS model

It supports the switching between visible light model and thermal infrared model, and only supports the use of multi band cameras

8) Fusion

This part of the function is only applicable to the Littro dual spectrum camera.

9) Multiplication table update

Figure 2- 17 Multiplication table update

The magnification table types include visible light, infrared and laser. Click the file upload button to pop up the file selection interface. Select the corresponding update file to update the magnification table. Note: The suffix of magnification table file is txt. Do not close the system configuration interface during file upload, or the upload will stop.

10) Version and Language

Figure 2-18 Version and Language

It contains system version information.

The language supports simplified Chinese and English.

AI Restart: restart the device. After the restart, the software will automatically reconnect, which takes about 20 seconds.

Restore factory: reset the parameters in this interface to factory default parameters.

Firmware upgrade: The suffix of the firmware file is dev. The firmware upgrade process takes a long time. Do not close the system configuration interface during the upgrade process, or the upgrade will be interrupted.

2.5 PTZcontrol and video operation

2.5.1 Photography and video storage

Click button to activate photographing. If "local video recording" is selected, the photos are stored in the "image_normal" directory under the software installation directory.

Click to start video storage, and click again to end video storage. When the button is blue, it means that you are taking pictures.If you select "Local video recording", the video is stored in the "video_normal" directory under the software installation directory.If you want to play video with the player provided by the system, you need to install H264 decoder.

2.5.2 PTZ and lens control

This part of the menu includes lens zoom, PTZ zeroing, PTZ moving up, down, left, right and other controls, as shown in the following figure.

Figure 2- 18 PTZ and lens control button

The specific functions are described in the following table:

Table 2- 5 PTZ and lens control button

Button

Function description

Zoom lens out

Zoom lens in

Focus near

Focus far

The PTZ reset to zero position

PTZ move to vertical down, PTZ needs support this function

Upward movement

Downward movement

Moves to the left

moves to the right

Iris Control

2.5.3 Display control

This part of the menu includes PIP(picture in picture) switching and display control of interface buttons, as shown in the following figure.

Figure 2 - 20 Display Control Buttons

The specific functions are described in the following table:

Table 2-6 Display Control Buttons

Button

Function description

The display mode is divided into five types: visual in thermal, thermal in visual, full visual, full thermal and fusion mode. After selecting the display mode, the corresponding algorithm model will be automatically switched according to the display mode. It takes about 15 seconds to switch the algorithm model.

The device needs support this function.

After activation, hide all buttons.

2.6 Default Settings

The default parameters are shown in the following table.

Parameter name

Default Parameters

PTZ control

PTZ ID

1

Camera ID

1

Tracking control

Start frames

20

Max speed

20

Speed gradient

30

Difference

5

Integral

0

Manual speed

3

Object tracking

Buffer frame

80

Auto-zoom area

50

Min Obj focusing

10

Max Obj focusing

20

Target recapture interval

0

Auto-zoom

Off

Loss of follow-up

Off

Alarm and linkage

Intrusion alarm

Off

Equipment linkage

Off

Image Configuration

Resolution

1080P (This function is not configured after factory restoration)

Codec

H264 (This function is not configured after factory restoration)

Bit rate

4M (This function is not configured after factory restoration)

OSD

show

On

Photoelectric pod

Operating mode

Follow mode

display mode

White infrared

Pseudo color mode

White hot mode

Digital doubling

1

Local video recording

ON

AI-OSD

OFF

laser spot

100

Pitch angle setting

0

Heading angle setting

0

Auto focus

On

Algorithmic model

VIS model

Fusion

Restore to factory and do not configure this function

Version and language)

Version information

Restore to factory without operation

System language

Simplified Chinese (no operation after factory restoration)

Last updated